1. Fire separation measures should be taken between the loading and unloading (sorting) operation area and the storage area, and the structural stress system of the loading and unloading (sorting) operation area and the storage area should be relatively independent to ensure that there is no overall collapse in the event of a fire; The maximum allowable building area of the fire compartment in the loading and unloading (sorting) operation area can be determined by referring to Table 3.3.1 of the current national standard "Code for Fire Protection Design of Buildings" GB 50016-2006 for Class C factory buildings; The maximum allowable floor area of the storage area and the maximum allowable building area of the fire compartment can be determined in accordance with the provisions of Note 4 in Table 3.3.2 of the current national standard "Code for Fire Protection Design of Buildings".
The fire resistance rating of the logistics distribution center building should not be lower than level two. The logistics distribution center for steel structured shelves should use reinforced concrete columns, or steel columns should be coated with fire-resistant materials, or a combination of coatings and fire-resistant materials can be used to achieve the corresponding fire resistance limit specified in the specifications.
3. The number and width of safety exits, evacuation distance, and evacuation stairs in the loading and unloading (sorting) operation area and storage area should respectively comply with the relevant regulations of Class C factory buildings and warehouses in the current Code for Fire Protection Design of Buildings.
4. The loading and unloading (sorting) operation area and storage area should be equipped with automatic fire extinguishing systems, automatic alarm systems, and smoke exhaust facilities in accordance with the current national standard "Code for Fire Protection Design of Buildings".
5. The shelf building of the logistics distribution center should be equipped with a circular fire lane, and a fire fighting surface should be arranged within at least 1/4 of the length of the long side or the surrounding area, and not less than one long side length range. A staircase or entrance that leads directly to the outside should be set up within the fire fighting surface range, and there should be at least 15-18m of open space on one side of the fire fighting surface that can carry out fire operations.
Read recommendations:
6-Tier Steel Wire Shelf / Steel Wire Racking / Custom Steel Wire Racks
white metal garage shelving custom
Seize opportunities and meet challenges.metal garage shelving unit
Last article:4 tier steel wire shelf custom.Can warehouse shelves really improve the quality of warehouse managem
Next article:5 forms of low-temperature storage facilities
Popular Recommended Products
MZG Steel Storage Shelving 5-Tier with Wheels, Chrome
2023-10-25Wire Mesh Shelving Unit / Metal Wire Storage Rack / Custom Steel Wire Racks
2022-11-293-Tier TV Stand with Wood Top / TV Console Table With Open Storage Shelves on Wheels For Living Room
2022-12-053-Tier Metal Display Shelving / Wire Shelving Unit
2022-11-15Wire Shelving for Industrial Wire Rack with Storage boxes Heavy Duty Wire Shelving Unit
2022-12-05What are the types of storage shelves?
2022-12-16Why does the shelf deform?
2024-06-11metal display shelving.What is the development and progress of heavy-duty shelves
2023-10-17Warehousing shelves.cabinet shelf manufacture
2023-05-24Don't be afraid of trouble, those really fragrant "routines" for wardrobe storage and orga
2023-01-044 tier metal bookself company
2023-04-124 tier wire shelving unit Production
2023-04-122 tier steel wire shelf sales
2023-03-25wire kitchen/pantry shelving unit price
2023-04-12